destruction at ρ

w

 = 1.03 reached the yield strength; therefore, reinforcement up to 

 1

 %

w

=

 can be considered effective. 

With an increase of the reinforcement percentage in the range from 0.34 to 1.03, 

the strength of the samples increased up to two times.  

Analysis of experimental studies confirmed the kinematically possible failure 

schemes by shearing, adopted in theoretical solutions, and indicates the reliability of 
the joints calculating proposed method. 

The calculation of the contact-platform six-keyed joint with the dimensions of the 

slab bearing areas taken beyond the wall plane 1.2×8.1 m and a thickness of  
220 mm (the slab has 6 voids with a diameter of 159 mm). The ratio of the adopted key 

sizes (its depth to height) 

0.5

kk

lh=

, class of the monolithic concrete C20/25, the keys 

are reinforced with transverse reinforcement 4Ø6 A240С. The resulting calculated 
shear resistance f

sh

 is 3.11 MPa. A possible stress reduction for a round cross section 

of keys is taken into account by introducing a reduction factor of 0.9. The joint bearing 
capacity of the slab with wall panels in the reinforcement of all the keys is provided 
with a large margin and it is possible to reinforce only two, the rest keys can be 
provided for concrete.) with the cross-sectional dimensions of 150×600 mm allows one 
key to perceive  

The shear strength calculation of the longitudinal keyway between the slabs 

according to the proposed method takes into account the possibility of failure along an 
inclined plane within the joint thickness, and the shear strength is 72.5 N/m. The key 
joints calculation of the slabs on horizontal loads shows that the keyed seam (Fig. 3the 
force V

Rd,k

 =325.4 kN. The number of keys along the length of the slab depends on the 

value of the horizontal force acting in the floor slab disk. For the further development 
of large-panel housing construction, a promising direction is the integrated use of 
reinforced ceramsite concrete to create lightweight structures. 

Improving the joints of precast-cast-in-place structural systems. ARKOS is 

one of the common structural systems of multi-storey frame buildings [11], in which: 
precast-cast-in-place overlapping disks with the use of hollow-core slabs are made flat, 
without protruding parts into the volume of the premises (Fig. 4); with a given 
thickness  of 12 – 14 cm to the continuous floor slab, width of spans up to 7.2 m are 
ensured; in the design of floor slab discs, accounting for reactive thrust forces arising 
under load, which made it possible to reduce the consumption of steel for their 
reinforcement by 30–40%, was implemented. 

The slabs are supported on monolithic bearing girders with the help of concrete 

keys formed in the voids of the slabs at their ends surface when girders concreting.  

The combined work of the slabs among themselves and the bracing girders is also 

ensured by the work of the keys. 

- 31 -