Present work authors in [24] article have suggested that such components have
not only different morphologies, but also origin genesis, associated with zinc
appearance in Cu-Al-Fe system. Measurement of components concentration in studied
bronze samples α-Cu solid solution crystals have been carried out by energy-dispersive
analysis method. Examples of quantitative components microanalysis are shown in
Figure 3.4. Measurement results are presented in Table 3.1.
a
b
a – Spectrum 2, b – Spectrum 3
Figure 3.4. Results of bronze BrA9Zh3L quantitative X-ray energy-dispersive
analysis
Source: analyzed by the authors
Table 3.1 Energy-dispersive analysis results of elements content in α-Cu solid
solution
Spectrum №
Components content, wt. %
Aluminum
Iron
Zinc
Σ=Al+Fe+Zn
Cu
Spectrum 1
7.68
1.25
4.17
13.10
The base
Spectrum 2
8.06
1.14
4.00
13.20
Spectrum 3
7.79
1.28
4.42
13.49
Spectrum 4
8.08
1.31
4.19
13.58
Spectrum 5
8.09
1.29
4.48
13.86
Spectrum 6
7.35
1.66
4.90
13.91
Spectrum 7
7.75
1.63
4.38
13.76
Spectrum 8
7.72
1.33
4.47
13.52
Source: calculated and completed by the authors