a – Spectrum 4, b – Spectrum 5 

Figure 3.5. Results of bronze BrA9Zh3L quantitative X-ray energy-dispersive 

analysis 

Source: analyzed by the authors 

 
Examples of Al, Fe and Zn amount in eutectoid structural component analysis are 

shown in Figure 3.5. Measurement results are presented in Table 3.2. 

Crystals of α-Cu solid solution X-ray energy-dispersive analysis data (see Table 

3.1) show the quantitative values arrays densities of aluminum content (7,35 ... 8,09 
wt. %), iron (1,14 ... 1,66 wt. %) and zinc (4,00 ... 4,90 wt. %) regardless of Zn 
concentration in alloy. 

Table 3.2 Energy-dispersive analysis results of Al, Fe and Zn content in 

eutectoid structural component 

Spectrum # 

Al, Fe and Zn content, wt. % 

Aluminum 

Iron 

Zinc 

Σ=Al+Fe+Zn 

Cu 

Spectrum 1 

11.82 

1.40 

3.40 

16.62 

The 

base 

Spectrum 2 

8.59 

0.99 

6.50 

16.08 

Spectrum 3 

8.24 

1.26 

6.41 

15.91 

Spectrum 4 

12.41 

1.23 

3.06 

16.70 

Spectrum 5 

10.81 

0.88 

4.54 

16.23 

Spectrum 6 

8.97 

0.97 

4.88 

14.82 

Spectrum 7 

11.47 

1.01 

3.70 

16.18 

Spectrum 8 

11.92 

1.43 

4.54 

17.89 

Spectrum 9 

12.72 

1.05 

4.15 

17.92 

Source: calculated and completed by the authors 

 