Figure  2. Control-flow chart for calculation of efficiency factor of closed-type 

heat storage device 

Source: developed by authors [8]  
 
Q

in

 is heat input for close-type heat storage device, kJ:  

ev

w

h

w

s

h

w

cp

h

cas

h

h

ads

des

in

Q

Q

Q

Q

Q

Q

Q

Q

+

+

+

+

+

+

=

.

.

,                    (3) 

where 

 

 

,

 

,

 

,

 

,

 

,

 

,

.

.

ev

w

h

w

s

h

w

cp

h

cas

h

h

ads

des

Q

Q

Q

Q

Q

Q

Q

are heat inputs for desorption, 

heating of adsorbent, device casing, coil pipe, water in the evaporator, adsorbed water, 
water evaporation, kJ.   

Inputs for warming materials and device units are calculated by conventional 

formula:  

Q=M∙C∙Δt                                                 (5) 

Computer data 

input 

=0.1 

Calculation of mass transfer coefficient 
Calculation of adsorption value 
Calculation of useful adsorption heat 
Calculation of heat inputs for process:  
1)Heat for adsorbent warming 
2)Heat for warming-up of device casing  
3) Heat for heating the coil pipe 
4)Heat for desorption 
5)Heat for heating the water in the tank 
6)Heat on evaporation of water in the tank 
7)Heat for adsorbed water warming 

Calculation of efficiency coefficient 

w= w + 0.1 

Results 

output 

End 

If w<1 

Beginning 

- 508 -